ASSESSMENT OF MBT-WASTE - A NEW APPROACH TO AVOID FAILURES BY MEASURING RESPIRATION ACTIVITY

The Austrian Landfill Ordinance regulates limit values for Respiration Activity (= “Atmungsaktivität”) RA4 (AT4) < 7 mg O2/g DM, Gas Generation Sum GS21 < 20 Nl/kg DM and alternatively Gas Evolution (= “Gasbildung”) GB21 < 20 Nl/kg DM). In 2004 Austrian Standards for these parameters were established (OE-NORM S2027-1to3). Research at the Institute of Waste Management, BOKU-University Vienna (=ABF-BOKU), has demonstrated a good correlation between GS21 and AT4. The correlation coefficient for 70 samples (dark squares) is r = 0.94 (Figure 1). Nevertheless in Austria to assess the quality of MBT-output, both Respiration Activity plus Gas Generation Sum (or Gas Evolution) should be analyzed, because - as praxis showed – one of the biological tests sometimes show lower measured values caused by
retardant conditions for the microbial community.

In 2005 an amendment of the "Austrian Landfill Ordinance" came into effect (BGBl. Nr. 194/96) in Austria. Limit values of Respiration Activity (= "Atmungsaktivität") AT4 < 7 mg O2/g DM (dry mass), Gas Generation Sum GS21 < 20 Nl/kg DM and alternatively Gas Evolution (= "Gasbildung") GB21 < 20 Nl/kg DM were established. In 2004 Austrian Standards for these parameters followed. On one hand these tests are very time consuming (4 resp. 21 days), on the other hand in several cases lower findings may led to misinterpretation of MBT-Output (e.g. drying out of material, insufficient oxygen supply, production of metabolic products). Over the last 5 years at ABF-BOKU more efficient methods have been developed for use in the assessment of MBT-quality. Fourier Transform Infrared (FT-IR) and Thermogravimetric methods seem to be particularly promising. Statistical tools (multivariate data analysis, PLS-regression) have enabled development of models allowing an accurate interpretation of the FT-IR spectra. This paper presents first results of a study performed with the aim of developing a partial least squares regression model (PLS-R) of infrared spectra and "reliable values" of Respiration Activity for MBT waste to predict Respiration Activities of new samples and identify "lower findings".



Copyright: © IWWG International Waste Working Group
Quelle: Specialized Session E (Oktober 2007)
Seiten: 9
Preis: € 9,00
Autor: Dipl.-Ing Erwin Binner
Dr. Katharina Meissl
Maria Tesar
 
 Diesen Fachartikel kaufen...
(nach Kauf erscheint Ihr Warenkorb oben links)
 Artikel weiterempfehlen
 Artikel nach Login kommentieren


Login

ASK - Unser Kooperationspartner
 
 


Unsere content-Partner
zum aktuellen Verzeichnis



Unsere 3 aktuellsten Fachartikel

carboliq® - Direktverölung gemischter Kunststoffabfälle
© Witzenhausen-Institut für Abfall, Umwelt und Energie GmbH (4/2025)
Die Forderung nach Klimaneutralität dominiert die globale Diskussion über die Zukunft der Industriegesellschaft. Damit einher geht auch die Frage, wie der Umgang mit Kunststoffen in Zukunft erfolgen wird.

Nutzungskonflikt zwischen Carbon-Capture-Anlagen und Fernwärme?
© Witzenhausen-Institut für Abfall, Umwelt und Energie GmbH (4/2025)
Die EEW Energy from Waste GmbH (EEW) hat sich das Ziel gesetzt, bis 2045 klimaneutral zu werden. Mit 17 Standorten verfügt EEW über eine Verbrennungskapazität von ca. 5 Millionen Tonnen Abfall pro Jahr.

Abfall- und Kreislaufwirtschaft in Deutschland im internationalen Vergleich - Spitzenplatz oder nur noch Mittelmaß?
© Witzenhausen-Institut für Abfall, Umwelt und Energie GmbH (4/2025)
Neben der Umstellung der künftigen Energieversorgung auf ein zu 100 % erneuerbares Energiesystem ist die Abfall- und Kreislaufwirtschaft die zweite zentrale Säule im Rahmen der globalen Transformation in eine klimaneutrale Wirtschaft und Gesellschaft.